Indian Journal of Dental Research

ORIGINAL RESEARCH
Year
: 2010  |  Volume : 21  |  Issue : 4  |  Page : 496--499

Comparison of manual and physiologically molded denture bases in complete denture wearers


Lakshmipathy P Reddy1, Rajashekar Sangur2 
1 Department of Prosthodontics, K.L.E. Institute of Dental Sciences, Bangalore, Karnataka, India
2 Department of Prosthodontics, Rama Dental College-Hospital & Research Centre, Kanpur - 208 024, Uttar Pradesh, India

Correspondence Address:
Lakshmipathy P Reddy
Department of Prosthodontics, K.L.E. Institute of Dental Sciences, Bangalore, Karnataka
India

Background and Objectives: In complete denture wearers, the accumulation of food in the buccal vestibule is one of the factors causing discomfort to the patient. This study was conducted to evaluate the effect of mandibular denture buccal flange on food retention and to correlate between varying angulations of buccal flange of mandibular denture on food retention. Materials and Methods: Complete dentures were fabricated and the mandibular complete denture was duplicated. The existing (unduplicated) manually molded and physiologically molded dentures were tested for food retention. Twenty test particles having a diameter of 2±0.2 mm were placed on the middle part of the buccal flange and the subjects were instructed to expel the test particles by performing only functional movements of the buccal musculature. The numbers of residual test particles in the buccal vestibule were counted after 30s. The angulations of the denture buccal flange (duplicated) were measured with an optical bevel protractor and trimmed to 50° and the food retention test was performed. Similar tests were performed at 60°, 70° and 80° angulations. The data were evaluated using the Pearson correlation coefficient, One-way ANOVA test and Wilcoxon signed rank test. Results: The difference between the residual scores of manually molded and physiologically molded denture base was not significant. The difference between the residual scores at different angulations of the buccal flange of the denture was significant. Conclusion: Only the slope of the flange significantly affects the ability of subjects to expel the test particles.


How to cite this article:
Reddy LP, Sangur R. Comparison of manual and physiologically molded denture bases in complete denture wearers.Indian J Dent Res 2010;21:496-499


How to cite this URL:
Reddy LP, Sangur R. Comparison of manual and physiologically molded denture bases in complete denture wearers. Indian J Dent Res [serial online] 2010 [cited 2022 May 23 ];21:496-499
Available from: https://www.ijdr.in/article.asp?issn=0970-9290;year=2010;volume=21;issue=4;spage=496;epage=499;aulast=Reddy;type=0