Year : 2017 | Volume
: 28
| Issue : 3 | Page : 291-297 |
|
Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques |
|
Rathika Rai, S Arun Kumar, R Prabhu, Ranjani Thillai Govindan, Faiz Mohamed Tanveer
Department of Prosthodontics, Thai Moogambigai Dental College and Hospital, Chennai, Tamil Nadu, India
Click here for correspondence address and email
Date of Web Publication | 14-Jul-2017 |
|
|
 |
|
Abstract | | |
Background: Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. Aim: The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. Materials and Methods: This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Results and Conclusion: Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range. Keywords: Computer-aided design and computer-aided manufacturing, metal ceramic crowns, optical scanning
How to cite this article: Rai R, Kumar S A, Prabhu R, Govindan RT, Tanveer FM. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques. Indian J Dent Res 2017;28:291-7 |
How to cite this URL: Rai R, Kumar S A, Prabhu R, Govindan RT, Tanveer FM. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques. Indian J Dent Res [serial online] 2017 [cited 2023 Jun 9];28:291-7. Available from: https://www.ijdr.in/text.asp?2017/28/3/291/210687 |
Introduction | |  |
Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining success of the restoration. A well-fitting restoration needs to be accurate both along its margins and with regard to its internal surface.[1]
Studies in the literature have revealed that gingival tissue adjacent to the margin of an artificial crown contains chronic inflammatory infiltrate and this infiltrate is believed to have occurred due to accumulation of bacterial plaque at microscopic opening of margins of the restoration.[2] Poor internal fit of a coping can increase the thickness of the cement and thus influence the mechanical stability of dental restorations. The minimization of crown marginal gap and internal gap is an important goal in prosthodontics. Based on literature review, ideal marginal gap is 25–40 μm. According to McLean, the acceptable vertical marginal gap ranges between 120 μm,[3] ideal internal gap ranges between 20 μm and 40 μm, and internal gap ranges between 50 μm and 100 μm.[4]
In general, marginal gap and internal gap of restorations are very much influenced by clinical and laboratory factors. Clinical factors include geometry of tooth [5] preparation, type of finish line and degree of taper, impression materials, and cement used to lute the restoration in dental office.[6] Laboratory factors that affect marginal gap and internal gap are incompatibility of dental materials such as wax, die stone and casting investments, die spacer, and the casting techniques.
The fabrication of dental cast restorations with the base metal alloys by lost wax technique involves impression procedure, preparation of the die, fabrication of pattern, and investing and casting. Difficulties encountered during casting of base metal dental alloys limit their use.[7] Application of these alloys might be enhanced if casting procedure is completely eliminated and new techniques are used.[8] One of the new techniques for fabrication of alloy copings reported in the literature is direct metal laser sintering (DMLS).[9]
DMLS is a new technique that replaces conventional metal casting procedures.[10] DMLS is a computer-aided design and computer-aided manufacturing (CAD/CAM)-based technique in which frame works and metal copings can be designed and fabricated using cobalt-chromium (Co-Cr).[11],[12],[13],[14] Co-Cr powdered alloy used in this technique has slight variations in composition. The molybdenum content in the alloy powder used in DMLS is comparatively less than the alloy which is used for conventional casting. A high power laser beam is focused onto a bed of powdered metal (Co-Cr), these areas fuse into thin solid layer and another layer of powder is then laid down over this and the next slice of framework is produced and fused with the first until framework or coping is finished.[15]
The CAD/CAM process of producing copings by DMLS technique using automated scanning process and powerful computer-aided design software offers many advantages such as complete control over the framework and coping designing, margin placement, cement space maintenance, coping thickness, and pontic designs, as well as elimination of casting procedures.[16],[17]
Aim of the study
- To evaluate vertical marginal and internal gap of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression
- To evaluate vertical marginal and internal gap of metal ceramic crowns obtained by CAD/CAM technique using conventional impression by indirect optical scanning
- To evaluate vertical marginal and internal gap of metal ceramic crowns obtained by CAD/CAM technique using direct optical scanning
- To comparatively evaluate the vertical marginal and internal gap of metal ceramic crowns obtained from inlay casting wax pattern and crowns from CAD/CAM technique using conventional impression and crowns from CAD/CAM technique using indirect and direct optical scanning.
Materials and Methods | |  |
A custom-made stainless steel master model was prepared simulating the shape and dimension of a prepared tooth resembling the first molar using a computer numerical control milling machine.
The custom-made stainless steel master model and stainless steel former employed in this study was based on the model employed by Ushiwata and de Moraes.[4]
The sample is prepared to the shape and dimension of a prepared tooth resembling a maxillary first molar of 8 mm in cervical diameter, 7 mm in height, axial reduction of 1.2 mm, rounded axial line angles, 10° occlusal surface inclination, 135° chamfer finish line, and an occlusal bevel resembling functional cusp bevel of 45° [Figure 1]. | Figure 1: Stainless steel model and model former axial and occlusal view
Click here to view |
The first cylindrical section (C1) of the metal die was contiguous to tooth preparation finish line. The cylindrical section was 10 mm in height and 8 mm in diameter. The octagonal section (C2) was 8.3 mm in height and 13 mm in diameter. External surface of (C2) cylindrical section was equally divided into eight parts, which helps in placement of master model on the platform of the stereomicroscope. A custom-made stainless steel former was fabricated, such that the former could be accurately positioned over the stainless steel die. The stainless steel former was larger than the die in all dimensions by 0.5 mm uniformly [Figure 2]. This was done to maintain a space of 0.5 mm throughout between the die and the former. This space helped obtain the pattern copings with uniform thickness. The counterpart also had three vertical slits which acts as escape hole for the excess molten inlay casting wax that comes out during assembling of master die to the metal counterpart. | Figure 2: (a) Line diagram of custom made stainless steel model, (b) stainless steel former assembly in apposition
Click here to view |
An elastomeric impression of the custom-made stainless steel model was made using addition silicone (Aquasil, Dentsply) using two-stage technique. Type IV dental stone was mixed in w/p ratio as recommended by the manufacturer. The mixed die stone material was poured into the mold. The master die was treated with die hardener and 3 coats of die spacer (YETI, Germany) to create 30 μ space, simulating the luting cement space. Die lubricant (YETI, Germany) was applied onto the die and the fitting surface of the stainless steel former. The inlay casting wax (GC Corporation, Tokyo, Japan) was melted and painted on the type IV die. The master die and stainless steel die former assembly was held together for 1 min with finger pressure. The stainless steel former helps in obtaining a uniform wax pattern thickness of 0.5 mm.
Sprue was attached to the patterns and was invested. Burnout procedure and casting were performed in the regular conventional way following the manufacturers' instructions.
Fabrication of direct metal laser sintering coping using indirect optical scanning
The type IV die stone master die is scanned using D700 three-dimensional scanner which guarantees superior scanning results. The scanner employs two cameras and three-axis motion system, which results in accuracy of the object geometry acquisition. The 3-axis allows the object to be tilted, rotated, and translated so as to be scanned from any viewpoint, making 3-axis the optimal number of axis for a scanning volume corresponding to a dental model. The desired spacer thickness of 30 μm is programmed 1 mm short to the margin. The nonuniform offsetting and shelling algorithm is proposed to create the coping shell model with uniform thickness of 0.5 mm. The stereolithography (STL) data thus obtained are forwarded to computer-aided manufacturing (CAM) bridge, which is a professional software for automatic part placement. From here, the data are forwarded to building chamber where infrared laser beam is used to fuse the (Co-Cr) powder, layer by layer to produce the solid object. Production begins once a layer of powder is spread across the build platform, which is then evenly spread with a powder leveling roller. The laser beam scans the powder surface heats the particles and fuses them. After the first layer solidifies, the built platform moves another layer of powder, which is again sintered by the laser beam. The process is repeated until the coping is completed [Figure 3]. | Figure 3: (a) Conventional impression and master die, (b) scanning of master die, (c) margin location, (d) removed metal copings from the direct metal laser sintering table after completion of process
Click here to view |
Fabrication of direct metal laser sintering copings using direct optical scanning
The master metal die is scanned using Sirona intraoral scanner which guarantees superior scan. The STL data thus obtained are forwarded to CAM bridge. Then, the fabrication of DMLS copings was processed similar to that of Group (G2) [Figure 4]. | Figure 4: (a) Direct optical scanning of metal die, (b) scanning machine, (c) buccal view of scanned die, (d) occlusal view of scanned die, (e) completed metal copings
Click here to view |
Cementation of the porcelain-fused-to-metal crowns on master model
All thirty test samples were applied with a thin layer of pressure-indicating paste and cemented on the stainless steel die and a load of 2 kg is applied for 2 min, with metal ceramic crowns against the vertical axis of the tooth preparation section using a surveyor. The 2 kg load was placed over a custom made metal platform which had a slot in the center to engage the vertical arm of the surveyor [Figure 5]. This same procedure was followed for applying load for all the thirty test samples. This was done to simulate a coping cemented in the oral condition. Pressure-indicating paste was used for cementing purpose as it was easy for retrieval of the copings from the model without any damage to the coping and the master model. The vertical marginal discrepancy was determined as the maximum distance between the tooth preparation margin and the most apical part of the casting margin in a plane parallel to the long axis of the tooth preparation. | Figure 5: Dental surveyor along with custom made platform and 2 kg weight
Click here to view |
Measurement of vertical and marginal gaps
All the thirty test samples of groups G1, G2, and G3 were evaluated for vertical marginal gap and internal gap employing Stereomicroscope in microns. The vertical marginal gap at the margin of the casting and the die was measured using stereomicroscope [Figure 6]a. Marginal gap was measured to the nearest micron on each cast coping at the eight predetermined reference areas on the stainless steel master model separated by 45° [Figure 6]b. For each sample, the mean vertical marginal gap was obtained and the overall mean vertical marginal gap for that test group was obtained from these means. The results thus obtained were statistically analyzed [Table 1]. | Figure 6: (a) Schematic representation of 8 predetermined reference areas to be measured for vertical marginal gap, (b) vertical marginal gap of metal ceramic crowns obtained from stereomicroscope. Metal ceramic crowns obtained from conventional lost wax technique, Metal ceramic crowns obtained from indirect optical scanning, Metal ceramic crowns obtained from direct optical scanning
Click here to view |
 | Table 1: Mean vertical marginal gap values of three groups (Group 1, Group 2, and Group 3)
Click here to view |
Measurement of internal gaps for G1, G2, and G3
The internal gap was evaluated after cementation of the copings using pressure-indicating paste. The luted crowns are retrieved along with the pressure-indicating paste after 10 min. The heavy body is injected on to the internal surface of the crown with pressure-indicating paste. The heavy body along with pressure-indicating paste was retrieved as a single block and heavy body is again injected on to the external surface of the crown surface of the pressure-indicating paste. Moreover, the blocks are sectioned into three pieces with two slices, namely, slice a and slice b and measurements are made at 18 points [Figure 7]a. | Figure 7: (a) Schematic representation of 4 predetermined reference areas to be measured for internal gap, (b) internal gap of metal ceramic crowns obtained from stereomicroscope. Metal ceramic crowns obtained from conventional lost wax technique, Metal ceramic crowns obtained from indirect optical scanning, Metal ceramic crowns obtained from direct optical scanning
Click here to view |
The internal gap between the inner surface of the heavy body and the external surface of the heavy body with pressure-indicating paste was measured, using stereomicroscope [Figure 7]b. The measurements thus obtained were tabulated. For each sample, the mean internal gap was obtained and the overall mean internal gap for that test group was obtained from these means. The results thus obtained were statistically analyzed [Table 2] and [Table 3]. | Table 2: Mean internal gap values on occlusal surfaces of three groups (Group 1, Group 2, and Group 3)
Click here to view |
 | Table 3: Mean internal gap values on axial surfaces of three groups (Group 1, Group 2, and Group 3)
Click here to view |
All statistical calculations were performed using Microsoft Excel (Microsoft, USA). Post hoc Tukey's test was used for statistical analysis. One-way analysis of variance (ANOVA) method was used to compare the mean values, standard deviation, F value, and P value of each test group, and P< 0.05 was considered statistically significant.
Results | |  |
Inference
[Table 4] shows the comparison of mean values of the vertical marginal gap obtained for each of the three groups. One-way ANOVA test was used to calculate the “P” value. Since the P< 0.05, there is a significant difference between three groups with regard to vertical marginal gap. Multiple range test by post hoc Tukey's test was employed to identify significant groups at 5% level. The mean vertical gap was statistically significant from each other. Group 3 showed least mean vertical marginal gap followed by Groups 2 and 1. | Table 4: Test of significance for the mean vertical marginal gap obtained from three groups (Group 1, Group 2, and Group 3)
Click here to view |
Inference
[Table 5] and [Table 6] show the comparison of mean value of the internal gap obtained for each of the three groups. One-way ANOVA was used to calculate the “P” value. Since the P< 0.05, there is a significant difference between the three groups with regard to internal gap. Multiple range test by post hoc Tukey's test was employed to identify significant groups at 5% level. Group 3 showed least mean internal gap. The mean internal gap was statistically significant from each other. Group 3 showed least mean vertical marginal gap followed by Groups 2 and 1. | Table 5: Test of significance for the mean internal gap on occlusal surfaces from three groups (Group 1, Group 2, and Group 3)
Click here to view |
 | Table 6: Test of significance for the mean internal gap on axial surfaces from three groups (Group 1, Group 2, and Group 3)
Click here to view |
Discussion | |  |
There are many clinical and laboratory factors responsible for the marginal and internal adaptation of dental cast restorations.[18],[19] Technical errors such as damage to the margins during die trimming, excessive thickness of die spacer, inaccurate wax adaptation, incorrect investments, and casting failures may occur. To minimize marginal and internal fit inaccuracies, the following methods and technique have been advocated by various authors:[17],[20],[21] overwaxing the margin of wax pattern, removing wax from internal surface of wax pattern,[22] die relief with application of die spacer, internal relief of cast restoration by sandblasting, mechanical milling, acid etching, electrochemical milling, and occlusal venting for escape of restoration.[7],[8],[23],[24]
In DMLS technique, Co-Cr powdered alloy is used in composition. The molybdenum content in the alloy powder used in DMLS is comparatively less than the alloy which is used for conventional casting. This new technique produces high accuracy, detailed resolution, good surface quality, and excellent mechanical properties.[25],[26],[27],[28],[29],[30],[31],[32]
The basic data obtained in this study showed the mean vertical marginal gap of 122.55 μm for metal ceramic crowns obtained from inlay casting wax patterns (G1), 72.68 μm for metal ceramic crowns obtained from indirect optical scanning of the master die (G2), and 36.38 μm for metal ceramic crowns obtained from direct optical scanning of the metal die (G3). This study was in congruence with Baig et al.[33],[34] who concluded that after casting, marginal gap ranged from 40 μm to 61.5 μm with a marginal gap of 120 μm which is the maximum clinical acceptable gap.[35] Similarly, Dedmon [10] stated that mean un-cemented marginal openings were 105 and 95 μm for vertical and horizontal openings, respectively.
Mean vertical marginal gap for metal ceramic crowns obtained from direct optical scanning of the metal die (G3) was 36.38 μm, showing comparatively lesser than the other two groups which could be attributed to the fact that this process has completely eliminated casting and manual errors, yields good results, compared to induction casting procedure which was used to melt the alloy.[8],[34],[36] Results of this study regarding the vertical marginal gap of all 30 copings were merely in acceptable range and in consensus with those of Dedmon,[10] White et al.,[24] Fusayama,[1] Hung et al.,[12] and Schwartz et al.[37]
The data obtained from this study showed that the mean internal gap for metal ceramic crowns obtained from inlay casting wax pattern was 87.6 μm (G1), metal ceramic crowns obtained from indirect optical scanning of the master die was 66.75 μm (G2), and metal ceramic crowns obtained from indirect optical scanning of the master die was 32.97 μm (G3).
The mean internal gap of G1 was 87.60 μm which was statistically more compared to G2, the discrepancies between mold expansion and casting shrinkage could be the reason for this. The mean internal gap of G2 was 66.75 μm which was statistically significant than G1. G3 showed a mean internal gap of 32.97 μm. Ucar et al.[38] did a study on internal fit evaluation of crowns fabricated using conventional casting technique and Laser sintered technology. Results from their study showed that the mean internal gap widths of cast Co-Cr copings were 87.6 μm and that of laser sintered technique was 32.97–66.75 μm which were in acceptance with the results obtained in this study.[17],[30] Bindl et al.[39] reported internal gap width of 81 μm to 136 μm for different all-ceramic CAD/CAM crowns which were greater than the mean internal gap found in this study.
Conclusion | |  |
Vertical marginal and internal gap was measured for all thirty test samples using Stereomicroscope in microns.
- The order of discrepancy of vertical marginal gap is as follows:
- Minimum vertical marginal gap for metal ceramic crowns obtained from direct optical scanning (G3) (31.9 μm) followed by from indirect optical scanning (G2) (70.4 μm) followed by conventional lost wax method (G1) (110.15 μm).
- The order of discrepancy of internal gap is as follows:
- Minimum internal gap for metal ceramic crowns obtained from direct optical scanning (G3) (28.65 μm) followed by indirect optical scanning (G2) (62.86 μm) followed by from conventional lost wax method (G1) (81.49 μm).
Within the limitations of this study, it has been concluded that the metal ceramic crowns fabricated by CAD/CAM method from direct optical scanning had the least vertical marginal and internal gap.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References | |  |
1. | Fusayama T. Factors and technique of precision casting Part II. J Prosthet Dent 1959;9:1037-48. |
2. | Quante K, Ludwig K, Kern M. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology. Dent Mater 2008;24:1311-5.  [ PUBMED] |
3. | Siadat H, Mirfazaelian A, Alikhasi M. Scanning electron microscope evaluation of marginal discrepancy of gold and base metal implant-supported prostheses with three fabrication methods. J Prosthet Dent 2008;8:148-53. |
4. | Ushiwata O, de Moraes JV. Method for marginal measurements of restorations: Accessory device for toolmakers microscope. J Prosthet Dent 2000;83:362-6. |
5. | Iglesias A, Powers JM, Pierpont HP. Accuracy of wax, autopolymerized, and light-polymerized resin pattern materials. J Prosthodont 1996;5:201-5.  [ PUBMED] |
6. | Bottino MA, Valandro LF, Buso L, Ozcan M. The influence of cervical finish line, internal relief, and cement type on the cervical adaptation of metal crowns. Quintessence Int 2007;38:e425-32.  [ PUBMED] |
7. | Milan FM, Consani S, Correr Sobrinho L, Sinhoreti MA, Sousa-Neto MD, Knowles JC. Influence of casting methods on marginal and internal discrepancies of complete cast crowns. Braz Dent J 2004;15:127-32.  [ PUBMED] |
8. | Al Wazzan KA, Al-Nazzawi AA. Marginal and internal adaptation of commercially pure titanium and titanium-aluminum-vanadium alloy cast restorations. J Contemp Dent Pract 2007;8:19-26. |
9. | Beuer F, Aggstaller H, Richter J, Edelhoff D, Gernet W. Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 2009;40:243-50.  [ PUBMED] |
10. | Dedmon HW. The relationship between open margins and margin designs on full cast crowns made by commercial dental laboratories. J Prosthet Dent 1985;53:463-6.  [ PUBMED] |
11. | Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989;62:405-8.  [ PUBMED] |
12. | Hung SH, Hung KS, Eick JD, Chappell RP. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent 1990;63:26-31.  [ PUBMED] |
13. | Hunter AJ, Hunter AR. Gingival crown margin configurations: A review and discussion. Part I: Terminology and widths. J Prosthet Dent 1990;64:548-52.  [ PUBMED] |
14. | Abou Tara M, Eschbach S, Bohlsen F, Kern M. Clinical outcome of metal-ceramic crowns fabricated with laser-sintering technology. Int J Prosthodont 2011;24:46-8.  [ PUBMED] |
15. | Juntavee N, Millstein PL. Effect of surface roughness and cement space on crown retention. J Prosthet Dent 1992;68:482-6.  [ PUBMED] |
16. | Beuer F, Aggstaller H, Juliane R, Daniel E, Wolfgang G. Influence of preparation angle on marginal fit and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 2009;4:57-65. |
17. | Gonzalo E, Suárez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 2009;102:378-84. |
18. | Groten M, Axmann D, Pröbster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 2000;83:40-9. |
19. | Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia copings: Comparison between various manufacturing processes. J Prosthet Dent 2011;105:249-55.  [ PUBMED] |
20. | Akova T, Ucar Y, Tukay A, Balkaya MC, Brantley WA. Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain. Dent Mater 2008;24:1400-4.  [ PUBMED] |
21. | Baig MR, Tan KB, Nicholls JI. Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. J Prosthet Dent 2010;104:216-27.  [ PUBMED] |
22. | Plekavich EJ, Joncas JM. The effect of impression-die systems on crown margins. J Prosthet Dent 1983;49:772-6.  [ PUBMED] |
23. | Ibrahim D, Broilo TL, Heitz C, de Oliveira MG, de Oliveira HW, Nobre SM, et al. Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy. J Craniomaxillofac Surg 2009;37:167-73.  [ PUBMED] |
24. | Fusayama T. Factors and technique of precision casting Part I. J Prosthet Dent 1959;9:468-85. |
25. | Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001;26:367-74.  [ PUBMED] |
26. | Suárez MJ, González de Villaumbrosia P, Pradíes G, Lozano JF. Comparison of the marginal fit of Procera AllCeram crowns with two finish lines. Int J Prosthodont 2003;16:229-32. |
27. | Takahashi T, Gunne J. Fit of implant frameworks: An in vitro comparison between two fabrication techniques. J Prosthet Dent 2003;89:256-60. |
28. | Luthardt RG, Bornemann G, Lemelson S, Walter MH, Hüls A. An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont 2004;17:680-5. |
29. | el-Ebrashi MK, Craig RG, Peyton FA. Experimental stress analysis of dental restorations. VI. The concept of proximal reduction in compound restorations. J Prosthet Dent 1969;22:663-70. |
30. | Wiltshire WA, Ferreira MR, Ligthelm AJ. Allergies to dental materials. Quintessence Int 1996;27:513-20. |
31. | Christensen GJ. In-office CAD/CAM milling of restorations: The future? J Am Dent Assoc 2008;139:83-5. |
32. | Bindl A, Windisch S, Mörmann WH. Full-ceramic CAD/CIM anterior crowns and copings. Int J Comput Dent 1999;2:97-111. |
33. | Palomo F, Peden J. Periodontal considerations of restorative procedures. J Prosthet Dent 1976;36:387-94. |
34. | Örtorp A, Jönsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study. Dent Mater 2011;27:356-63. |
35. | Tan PL, Gratton DG, Diaz-Arnold AM, Holmes DC. An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations. J Prosthodont 2008;17:378-83. |
36. | Holden JE, Goldstein GR, Hittelman EL, Clark EA. Comparison of the marginal fit of pressable ceramic to metal ceramic restorations. J Prosthodont 2009;18:645-8. |
37. | White SN, Yu Z, Tom JF, Sangsurasak S. In vivo marginal adaptation of cast crowns luted with different cements. J Prosthet Dent 1995;74:25-32. |
38. | Schwartz IS. A review of methods and techniques to improve the fit of cast restorations. J Prosthet Dent 1986;56:279-83. |
39. | Ucar Y, Akova T, Akyil MS, Brantley WA. Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: Laser-sintered Co-Cr crowns. J Prosthet Dent 2009;102:253-9. |

Correspondence Address: Faiz Mohamed Tanveer No. 331, TTK Road, Royapettah, Chennai - 600 014, Tamil Nadu India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/ijdr.IJDR_81_17

[Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7]
[Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6] |
|
This article has been cited by | 1 |
Evaluation of marginal and internal fit of lithium disilicate and zirconia all-ceramic CAD-CAM crowns using digital impressions: A systematic review |
|
| Ilser Turkyilmaz, Merve Benli, Sarah Yun | | Primary Dental Journal. 2023; 12(1): 88 | | [Pubmed] | [DOI] | | 2 |
Comparative Evaluation of Retention and Vertical Marginal Accuracy of Co–Cr Copings Fabricated Using Three Different Techniques: An In Vitro Study |
|
| Ajay V Sabane, Pankaj P Kadam, Rupali Patil, Bhagyashree G Kalsekar, Paresh V Gandhi, Nishita S Bhosale | | The Journal of Contemporary Dental Practice. 2023; 23(10): 991 | | [Pubmed] | [DOI] | | 3 |
Marginal and Internal Gap of Metal Copings Fabricated Using Three Types of Resin Patterns with Subtractive and Additive Technology: An In Vitro Comparison |
|
| Hemavardhini Addugala, Vidyashree Nandini Venugopal, Surya Rengasamy, Pradeep Kumar Yadalam, Nassreen H. Albar, Ahmed Alamoudi, Sarah Ahmed Bahammam, Bassam Zidane, Hammam Ahmed Bahammam, Shilpa Bhandi, Deepti Shrivastava, Kumar Chandan Srivastava, Shankargouda Patil | | Materials. 2022; 15(18): 6397 | | [Pubmed] | [DOI] | | 4 |
Evaluation of marginal/internal fit of fixed dental prostheses after digital, conventional, and combination impression techniques: A systematic review |
|
| Katia Sarafidou, Maria Chatziparaskeva, Dimitrios Chatzikamagiannis, Vasileios Mpotskaris, Dimitrios Tortopidis, Athina Bakopoulou, Maria Kokoti | | European Journal of Oral Sciences. 2022; | | [Pubmed] | [DOI] | | 5 |
Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An In Vitro Study |
|
| Jose Rosas, Frank Mayta-Tovalino, Violeta Malpartida-Carrillo, Arnaldo Munive Degregori, Roman Mendoza, Maria E. Guerrero, Zohaib Khurshid | | International Journal of Dentistry. 2021; 2021: 1 | | [Pubmed] | [DOI] | | 6 |
Marginal and internal adaptation of single crowns and fixed dental prostheses by using digital and conventional workflows: A systematic review and meta-analysis |
|
| Mahya Hasanzade, Mahdi Aminikhah, Kelvin I. Afrashtehfar, Marzieh Alikhasi | | The Journal of Prosthetic Dentistry. 2021; 126(3): 360 | | [Pubmed] | [DOI] | | 7 |
Effect of different finish line preparations on the marginal and internal adaptation of cobalt-chromium metal alloy copings fabricated by using CAD-CAM technology: A systematic review and meta-analysis |
|
| Naisargi Shah, Praveen Badwaik, Vidhi H. Sheth, Vishrut Bhatnagar, Nikhil Bhanushali, Prashant Patil | | The Journal of Prosthetic Dentistry. 2021; | | [Pubmed] | [DOI] | | 8 |
Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes |
|
| Nadine Freifrau von Maltzahn, Florian Bernhard, Philipp Kohorst | | The Journal of Advanced Prosthodontics. 2020; 12(2): 100 | | [Pubmed] | [DOI] | | 9 |
Evaluation of Effect of Fabrication Steps on Marginal Adaptation of CAD/CAM Zirconia-based Crowns in Comparison to Sintered PFM Crowns: An In Vitro Study |
|
| KS Sumanth, S Poovani, NK Sonnahalli | | International Journal of Prosthodontics and Restorative Dentistry. 2020; 10(4): 151 | | [Pubmed] | [DOI] | | 10 |
In Vivo and In Vitro Comparison of Internal and Marginal Fit of Digital and Conventional Impressions for Full-Coverage Fixed Restorations: A Systematic Review and Meta-analysis |
|
| Mahya Hasanzade,Mohammadjavad Shirani,Kelvin I. Afrashtehfar,Parisa Naseri,Marzieh Alikhasi | | Journal of Evidence Based Dental Practice. 2019; 19(3): 236 | | [Pubmed] | [DOI] | | 11 |
In Vivo and In Vitro Comparison of Internal and Marginal Fit of Digital and Conventional Impressions for Full-Coverage Fixed Restorations: A Systematic Review and Meta-analysis |
|
| Mahya Hasanzade,Mohammadjavad Shirani,Kelvin I. Afrashtehfar,Parisa Naseri,Marzieh Alikhasi | | Journal of Evidence Based Dental Practice. 2019; 19(3): 236 | | [Pubmed] | [DOI] | | 12 |
The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy |
|
| Mitra Farzin,Rashin Giti,Amin Asalforush-Rezaiye | | Materials. 2018; 11(4): 478 | | [Pubmed] | [DOI] | | 13 |
The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy |
|
| Mitra Farzin,Rashin Giti,Amin Asalforush-Rezaiye | | Materials. 2018; 11(4): 478 | | [Pubmed] | [DOI] | |
|
|
 |
 |
|
|
|
|
|
|
Article Access Statistics | | Viewed | 11600 | | Printed | 545 | | Emailed | 0 | | PDF Downloaded | 328 | | Comments | [Add] | | Cited by others | 13 | |
|

|