Evaluation of effect of recasting of nickel-chromium alloy on its castability using different investment materials: An in vitro study


1 Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Karnataka, India
2 Department of Prosthodontics and Crown and Bridge, A. J. Institute of Dental Sciences, Mangalore, Karnataka, India

Correspondence Address:
Shobha J Rodrigues
Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.183136

Rights and Permissions

Context: Castability has been found to be affected by many aspects of the entire casting system. Very few references in dental literature are available regarding recasting of the base metal alloys. Aims: To evaluate and compare the castability of fresh and reused nickel-chromium alloy and to evaluate the effect of two brands of investment materials on castability of nickel-chromium alloy. Subjects and Methods: For the experimental purpose of evaluation of the effect of recasting of nickel-chromium alloy on its castability, different percentages of new and casted alloy (Nickel-chromium alloy-(Wirolloy NB, Type 4 (Ni-67%; Cr-25%; Mo-5%; Si-1.5%; Mn, Nb, B, C each <1%) and two commercial brands of investment materials namely, Deguvest Impact (Degudent; Dentsply Germany) and Bellavest SH (Degudent; Dentsply Germany) was used to obtain 30 samples. Castability value was obtained using Whitlock's formula. Student t-test and one way ANOVA using SPSS 20.0 software was done. Results: The results of this study confirm earlier works that demonstrate that there is no significant difference in castability values of new and recast alloys. In addition, it also demonstrated, there was no difference in castability using Deguvest Impact and Bellavest SH investment materials. Conclusions: Within the limitations of the study, it was concluded that there was no significant difference found in castability of different percentage combinations of new and once casted alloy using two investment materials. The addition of new alloy during recasting to maintain the castability of nickel-chromium alloy may therefore not be required.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed2345    
    Printed81    
    Emailed0    
    PDF Downloaded147    
    Comments [Add]    

Recommend this journal