Comparative evaluation of stresses in tooth implant connected fixed partial denture by varying the implant design and position: A 3D finite element study


Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education and Research University, Chennai, Tamil Nadu, India

Correspondence Address:
K V Pratheep
Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education and Research University, Chennai, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9290.118388

Rights and Permissions

Aim: This study aims at evaluating stresses generated in a fixed tooth to implant connected fixed partial denture (FPD) by finite element method by varying implant design and position, in unilateral distal extension cases, i.e. for replacing mandibular 1 st and 2 nd molars. Materials and Methods: Four models were created, Model 1-A finite element model (FEA) model of a crestal implant-tooth connected metal ceramic FPD with pontic in 36 region. The 35 region simulated the second premolar. Model 2-A FEA model of a basal implant-tooth connected metal ceramic FPD. Model 3-A FEA model of a crestal implant in 36 region connected to tooth 35 and cantilevered posteriorly with pontic in 37 region, made of metal ceramic. Model 4-A FEA model of a basal implant in 36 region connected to tooth 35 and cantilevered posteriorly with pontic in 37 region, made of metal ceramic. A vertical force of 100N directed evenly on the nodes on the occlusal surface of each of the three crowns. The models displayed stress both numerically and by color coding. Results: On comparing models 1 and 2, the model 1 showed comparatively more stresses in crestal bone area of the implant. On comparing models 3 and 4, model 3 showed lesser von misses stress values. Conclusion: In case of tooth implant connected FPDs without any cantilevers, basal implants show better stress distribution when compared to crestal implants. In case of cantilever designs, crestal implant design showed lower stress values, but the difference in stresses were less.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed3250    
    Printed101    
    Emailed6    
    PDF Downloaded201    
    Comments [Add]    

Recommend this journal