Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
HOME | ABOUT US | EDITORIAL BOARD | AHEAD OF PRINT | CURRENT ISSUE | ARCHIVES | INSTRUCTIONS | SUBSCRIBE | ADVERTISE | CONTACT
Indian Journal of Dental Research   Login   |  Users online: 89

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         

 


 
ORIGINAL RESEARCH Table of Contents   
Year : 2011  |  Volume : 22  |  Issue : 2  |  Page : 237-241
Evaluation of an innovative radiographic technique - parallel profile radiography - to determine the dimensions of dentogingival unit


1 Department of Periodontics, VS Dental College and Hospital, Bangalore, Karnataka, India
2 Department of Periodontics, Jodhpur Dental College General Hospital, Jodhpur, India

Correspondence Address:
Gauri Gontiya
Department of Periodontics, Jodhpur Dental College General Hospital, Jodhpur
India
Login to access the Email id


DOI: 10.4103/0970-9290.84294

PMID: 21891892

Get Permissions

Background: Maintenance of gingival health is a key factor for longevity of the teeth as well as of restorations. The physiologic dentogingival unit (DGU), which is composed of the epithelial and connective tissue attachments of the gingiva, functions as a barrier against microbial entry into the periodontium. Invasion of this space triggers inflammation and causes periodontal destruction. Despite the clinical relevance of the determination of the length and width of the DGU, there is no standardized technique. The length of the DGU can be either determined by histologic preparations or by transgingival probing. Although width can also be assessed by transgingival probing or with an ultrasound device, they are either invasive or expensive Aims: This study sought to evaluate an innovative radiographic exploration technique - parallel profile radiography - for measuring the dimensions of the DGU on the labial surfaces of anterior teeth. Materials and Methods: Two radiographs were made using the long-cone parallel technique in ten individuals, one in frontal projection, while the second radiograph was a parallel profile radiograph obtained from a lateral position. The length and width of the DGU was measured using computer software. Transgingival probing (trans-sulcular) was done for these same patients and length of the DGU was measured. The values obtained by the two methods were compared. Pearson product correlation coefficient was calculated to examine the agreement between the values obtained by PPRx and transgingival probing. Results: The mean biologic width by the parallel profile radiography (PPRx) technique was 1.72 mm (range 0.94-2.11 mm), while the mean thickness of the gingiva was 1.38 mm (range 0.92-1.77 mm). The mean biologic width by trans-gingival probing was 1.6 mm (range 0.8-2.2mm). Pearson product correlation coefficient (r) for the above values was 0.914; thus, a high degree of agreement exists between the PPRx and TGP techniques. Conclusions: We conclude that the biologic width of the DGU in humans can be measured with the PPRx technique. The values obtained agree with the values obtained by transgingival probing, a technique considered standard so far. Thus, the PPRx technique offers a simple, concise, noninvasive, and reproducible method that can be used in the clinical setup to measure both the length and thickness of the DGU with accuracy.


[FULL TEXT] [PDF]*
Print this article     Email this article

 
 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 
 

 Article Access Statistics
    Viewed2670    
    Printed95    
    Emailed3    
    PDF Downloaded230    
    Comments [Add]    
    Cited by others 2    

Recommend this journal