Indian Journal of Dental ResearchIndian Journal of Dental ResearchIndian Journal of Dental Research
Indian Journal of Dental Research   Login   |  Users online: 62

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size         


ORIGINAL RESEARCH Table of Contents   
Year : 2010  |  Volume : 21  |  Issue : 4  |  Page : 506-511
Three-dimensional finite element analysis of the stress distribution pattern in the design modifications of U-shaped palatal major connector

Department of Prosthodontics and Implantology, Meenakshi Ammal Dental College and Hospital, Chennai, India

Correspondence Address:
Hariharan Ramakrishnan
Department of Prosthodontics and Implantology, Meenakshi Ammal Dental College and Hospital, Chennai
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/0970-9290.74219

Get Permissions

Background: The U-shaped maxillary major connector is considered to be the least-desirable design by many prosthodontists as it lacks rigidity, which is a primary requisite for a major connector. Aims and Objectives: Design modifications in the U-shaped palatal major connector are desired because it lacks rigidity. The study also aimed to determine the best design when a U-shaped palatal major connector is indicated for clinical use. Materials and Methods: The normal design and the design-modified models (modification 1, 2, 3, 4) were loaded at the functional cusps of the premolars and the molars with a magnitude of 200 N, 250 N and 300 N at angulations of 60 o and 90 o on both sides of the maxillary arch. Results for each loading were obtained as stress distribution colored images and numerical values were recorded. A three-dimensional finite element analysis study of the design-modified models was performed using two finite element softwares, namely PRO-E and IDEAS. Results: The least stress value of 7.86 Megapascals (MPa) at 200 N, 60 o was recorded for the double-thickness design, followed by design 1, which was 8.03 MPa. The least stress value for the palatal mucosa and ligament was provided by design modification 1 (0.5 mm-thick U-shaped connector, 9 mm anteroposteiorly, 14.6 mm laterally), which was 9.78 MPa and 2.98 MPa, respectively. Conclusion: The double-thickness group exhibited the least internal stress for the U-shaped major connector. However, it delivered the greatest stress to the palatal mucosa and the periodontal ligaments.

Print this article     Email this article

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *

 Article Access Statistics
    PDF Downloaded128    
    Comments [Add]    

Recommend this journal